Keller Minimal Windows Highline® is innovative premium glass facade system combines aesthetics with outstanding performance features. The slender and frameless glass facades enhance the pure minimalism of current architecture. The glass facade between two structural floors comprises thermally insulated, concealed aluminum frame profiles and is ideal wherever minimum facing width and maximum glazing height is desired. The flush-mounted or symmetrically alternating offset planes of the glass facade can be combined with ultra-slender design sliding doors to give the perfect solution for high-rise residential projects and business premises. Available as double- or triple glazing versions. Stability of the sliding system tested under extreme wind loads with a nominal load of 2,000 Pa (approx. 200 km/h) and a peak load of 3,000 Pa (approx. 250 km/h; with brief gusts of wind) in accordance with EN12210 and the classification C4/B5.
We distinguish 3 different design variants:
Type 1 – Glass-To-Glass, flush-surface glass facade with vertical 10 mm butt joint and SG bonding.
Type 2 – Semi-SG, flush-surface glass facade with vertical 20 mm butt joint outside and 22 mm design static profiles inside.
Type 3 – Cover-Cap-Look, flush-surface glass facade with 22 or 34 mm exterior cover in different design variants and vertical 22 or 34 mm design static profiles inside.
Type 1
minimal windows® highline | minimal windows®4+ highline | |
---|---|---|
Facing width from centre point | vertical 10 mm butt joint with SG bonding | vertical 10 mm butt joint with SG bonding |
Maximum leaf size | fixed lights with 12 m² / sliding up to 6.5 m² | fixed lights with 12 m² / sliding up to 7 m² |
Maximum overall height | 2.50 m | 2.80 m |
Maximum leaf weight | 500 kg | 650 kg |
Glass thickness | fixed light 36 mm, sliding leaf 34 mm, double insulation glazing or Heat Mirror® glass | 56 mm, triple insulation glazing or special glass type |
Thermal transmission coefficient | Uw ≥ 1.1 W/m²K | Uw ≥ 0.70 W/m²K |
Motorisation | option: E-drive (in sliding door configuration) | option: E-drive (in sliding door configuration) |
Barrier-free accessibility | DIN 18040-1, DIN 18040-2 | DIN 18040-1, DIN 18040-2 |
Air permeability | up to class 4 according to EN 12207 | up to class 4 according to EN 12207 |
Driving rain tightness | up to class 7A according to EN 12208 | up to class E1050 according to EN 12208 |
Resistance to wind load | up to class C4/B5 according to EN 12210 | up to class C5 according to EN 12210 |
Sound insulation | up to 39 dB achievable | up to 45 dB achievable |
Resistance to burglary | up to RC 2 according to EN 1627 | up to RC 2 according to EN 1627 |
Type 2
minimal windows® highline | minimal windows®4+ highline | |
---|---|---|
Facing width from centre point | vertical 20 mm butt join outside, 22 mm static post inside | vertical 20 mm butt join outside, 22 mm static post inside |
Maximum leaf size | fixed lights with 18 m² / sliding up to 8.5 m² | fixed lights with 18 m² / sliding up to 12 m² |
Maximum overall height | 4.00 m | 4.50 m |
Maximum leaf weight | 500 kg | 1000 kg |
Glass thickness | fixed light 36 mm, sliding leaf 34 mm, double insulation glazing or Heat Mirror® glass | 56 mm, triple insulation glazing or special glass type |
Thermal transmission coefficient | Uw ≥ 1.1 W/m²K | Uw ≥ 0.70 W/m²K |
Motorisation | option: E-drive (in sliding door configuration) | option: E-drive (in sliding door configuration) |
Barrier-free accessibility | DIN 18040-1, DIN 18040-2 | DIN 18040-1, DIN 18040-2 |
Air permeability | up to class 4 according to EN 12207 | up to class 4 according to EN 12207 |
Driving rain tightness | up to class 7A according to EN 12208 | up to class E1050 according to EN 12208 |
Resistance to wind load | up to class C4/B5 according to EN 12210 | up to class C5 according to EN 12210 |
Sound insulation | up to 39 dB achievable | up to 45 dB achievable |
Resistance to burglary | up to RC 2 according to EN 1627 | up to RC 2 according to EN 1627 |
Type 3
minimal windows® highline | minimal windows®4+ highline | |
---|---|---|
Facing width from centre point | exterior cover cap, 22 mm, 22 mm static post inside | exterior cover cap, 34 mm, 34 mm static post inside |
Maximum leaf size | fixed lights with 18 m² / sliding up to 8.5 m² | fixed lights with 18 m² / sliding up to 12 m² |
Maximum overall height | 4.00 m | 4.50 m |
Maximum leaf weight | 500 kg | 1000 kg |
Glass thickness | fixed light 36 mm, sliding leaf 34 mm, double insulation glazing or Heat Mirror® glass | 56 mm, triple insulation glazing or special glass type |
Thermal transmission coefficient | Uw ≥ 1.1 W/m²K | Uw ≥ 0.70 W/m²K |
Motorisation | option: E-drive (in sliding door configuration) | option: E-drive (in sliding door configuration) |
Barrier-free accessibility | DIN 18040-1, DIN 18040-2 | DIN 18040-1, DIN 18040-2 |
Air permeability | up to class 4 according to EN 12207 | up to class 4 according to EN 12207 |
Driving rain tightness | up to class 7A according to EN 12208 | up to class E1050 according to EN 12208 |
Resistance to wind load | up to class C4/B5 according to EN 12210 | up to class C5 according to EN 12210 |
Sound insulation | up to 39 dB achievable | up to 45 dB achievable |
Resistance to burglary | up to RC 2 according to EN 1627 | up to RC 2 according to EN 1627 |